instrument transformer,application of instrument transformer and construction_types of instrument transformer_type of CT transformer,VT transformer

instrument transformer,application of instrument transformer and construction,types of instrument transformer,type of CT transformer,VT transformer
what is instrument transformer?

  • instrument transformer is used in conjunction with any measuring instrument (i.e,ammeter , voltmeter , wattmeter ,watt hour-meter atc)or protective equipment(i.e relays) .
  • it utilize the current transformation and voltage transformation properties to measures high ac current. 
Global Instrument Transformer Market, Global Instrument ...
Application of instrument transformer:-

  • for measurement of high ac current , it is usual to use low range ac ammeter with suitable shunt .
  • for measurement  of high ac voltage ,low range ac voltmeters are used with high resistance connected in series.
  • for measurement of very high ac current and voltage ,we cannot use these methods . instead , we use specially constructed  HV instrument transformer to insulate the high voltage circuit from the measuring circuit in order to protect the measuring instrument from burning.
  • Application of instrument transformer in dc circuits for current and voltage measurement ,we use low range dc ammeter and voltmeter with rectifiers connected in their secondary circuits.
  • The vast primary application of instrument transformers is for the protection and control of power system and power equipment of high and very high ratings .
  • The working of these instrument transformers are similar to those of the ordinary transformers.What is Potential Transformer (PT)? Definition, Construction ...
There are two types of transformer .

  1. current transformer(ct)
  2. potential transformer(vt)
current transformer(CT)

  • A current transformer is a transformer ,which produces in its secondary  winding low current , which is proportional to the high current following in its primary winding .
  • The secondary current is usually much smaller in magnitude than the primary current.
  • The design of CT depends on which type of instrument is connected to its secondary measuring instrument or protective instrument .
  • measuring instrument CT is expected to give accurate result up to a maximum of 125% of its normal full-load rated current. 
  •  protective instrument CT is expected to be accuratr for up to 20 times of its normal full-load rated current (about 2000%of full load rated current).      
Construction of CT

  • ct has a primary coil of one or more turns made of thick wire connected in series with the line whose current   is to be measure .
  • The secondary consists of a large number of turns made of fine wire and s connected across and is connected across an ammeter or a relay's terminals .
  • According to construction there are two type of  CT transformer.


  1. window type 
  2. bar type 
Instrument Transformers - ppt video online download
Function of CT


  • The principle of a CT is to produce a proportional current at a level of magnitude ,which is suitable for the operation of low range measuring or protective devices such as indicating or recording instruments and relays.
  • The primary and secondary current are expressed as a ratio such as 100/5 or 1000/5.with 100/5 ratio CT, 100 Ampere flowing in the primary winding will result in 5 A  flowing in the secondary winding , provided that the correct rated burden is connected to the secondary winding . 
 Potential transformer(PT or VT)

  •  PT is a step down transformer having many primary turn but a few secondary turns.
  • In a step down transformer the voltage decreases and the current increases , thus voltage can be easily measured by using a low- range voltmeter instrument. 
  • the voltage is stepped-down in a known ratio called the voltage ratio.
   construction of PT

  • PT is a step down transformer having many primary winding turn but a few secondary winding turns that makes it a step-down transformer.
  • A voltmeter is connected to the secondary winding is usually a voltmeter of 150 V.